StandardDev
SCPI Commands :
READ:WLAN:MEASurement<instance>:MEValuation:MODulation:SEGMents:SDEViation
FETCh:WLAN:MEASurement<instance>:MEValuation:MODulation:SEGMents:SDEViation
CALCulate:WLAN:MEASurement<instance>:MEValuation:MODulation:SEGMents:SDEViation
- class StandardDevCls[source]
StandardDev commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Evm_All_Carr_Seg_1: enums.ResultStatus2: No parameter help available
Evm_All_Carr_Seg_2: enums.ResultStatus2: No parameter help available
Evm_Data_Carr_Seg_1: enums.ResultStatus2: No parameter help available
Evm_Data_Carr_Seg_2: enums.ResultStatus2: No parameter help available
Evm_Pilot_Carr_Seg_1: enums.ResultStatus2: No parameter help available
Evm_Pilot_Carr_Seg_2: enums.ResultStatus2: No parameter help available
Power_Backoff_Seg_1: enums.ResultStatus2: No parameter help available
Power_Backoff_Seg_2: enums.ResultStatus2: No parameter help available
Burst_Power_Seg_1: enums.ResultStatus2: No parameter help available
Burst_Power_Seg_2: enums.ResultStatus2: No parameter help available
Peak_Power_Seg_1: enums.ResultStatus2: No parameter help available
Peak_Power_Seg_2: enums.ResultStatus2: No parameter help available
Crest_Factor_Seg_1: enums.ResultStatus2: No parameter help available
Crest_Factor_Seg_2: enums.ResultStatus2: No parameter help available
Iq_Offset_Seg_1: enums.ResultStatus2: No parameter help available
Iq_Offset_Seg_2: enums.ResultStatus2: No parameter help available
Dc_Power_Seg_1: enums.ResultStatus2: No parameter help available
Dc_Power_Seg_2: enums.ResultStatus2: No parameter help available
Ltf_Power_Seg_1: enums.ResultStatus2: No parameter help available
Ltf_Power_Seg_2: enums.ResultStatus2: No parameter help available
Data_Power_Seg_1: enums.ResultStatus2: No parameter help available
Data_Power_Seg_2: enums.ResultStatus2: No parameter help available
Preamble_Power_Seg_1: enums.ResultStatus2: No parameter help available
Preamble_Power_Seg_2: enums.ResultStatus2: No parameter help available
- class ResultData[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Evm_All_Carr_Seg_1: float: No parameter help available
Evm_All_Carr_Seg_2: float: No parameter help available
Evm_Data_Carr_Seg_1: float: No parameter help available
Evm_Data_Carr_Seg_2: float: No parameter help available
Evm_Pilot_Carr_Seg_1: float: No parameter help available
Evm_Pilot_Carr_Seg_2: float: No parameter help available
Power_Backoff_Seg_1: float: No parameter help available
Power_Backoff_Seg_2: float: No parameter help available
Burst_Power_Seg_1: float: No parameter help available
Burst_Power_Seg_2: float: No parameter help available
Peak_Power_Seg_1: float: No parameter help available
Peak_Power_Seg_2: float: No parameter help available
Crest_Factor_Seg_1: float: No parameter help available
Crest_Factor_Seg_2: float: No parameter help available
Iq_Offset_Seg_1: float: No parameter help available
Iq_Offset_Seg_2: float: No parameter help available
Dc_Power_Seg_1: float: No parameter help available
Dc_Power_Seg_2: float: No parameter help available
Ltf_Power_Seg_1: float: No parameter help available
Ltf_Power_Seg_2: float: No parameter help available
Data_Power_Seg_1: float: No parameter help available
Data_Power_Seg_2: float: No parameter help available
Preamble_Power_Seg_1: float: No parameter help available
Preamble_Power_Seg_2: float: No parameter help available
- calculate() CalculateStruct [source]
# SCPI: CALCulate:WLAN:MEASurement<instance>:MEValuation:MODulation:SEGMents:SDEViation value: CalculateStruct = driver.multiEval.modulation.segments.standardDev.calculate()
Return the segment-specific single value results for 80+80 MHz SISO measurements. There are current, average, minimum, maximum and standard deviation results. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() ResultData [source]
# SCPI: FETCh:WLAN:MEASurement<instance>:MEValuation:MODulation:SEGMents:SDEViation value: ResultData = driver.multiEval.modulation.segments.standardDev.fetch()
Return the segment-specific single value results for 80+80 MHz SISO measurements. There are current, average, minimum, maximum and standard deviation results. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.
- read() ResultData [source]
# SCPI: READ:WLAN:MEASurement<instance>:MEValuation:MODulation:SEGMents:SDEViation value: ResultData = driver.multiEval.modulation.segments.standardDev.read()
Return the segment-specific single value results for 80+80 MHz SISO measurements. There are current, average, minimum, maximum and standard deviation results. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return:
structure: for return value, see the help for ResultData structure arguments.