TeDistribution
SCPI Commands :
READ:WLAN:MEASurement<Instance>:MEValuation:PVTime:MIMO<n>:TEDistrib
FETCh:WLAN:MEASurement<Instance>:MEValuation:PVTime:MIMO<n>:TEDistrib
CALCulate:WLAN:MEASurement<Instance>:MEValuation:PVTime:MIMO<n>:TEDistrib
- class TeDistributionCls[source]
TeDistribution commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Te_Percentage: enums.ResultStatus2: float Percentage of TEs Unit: %
Te_Outside: enums.ResultStatus2: decimal Number of detected TEs
Te_Total: enums.ResultStatus2: decimal Number of measured values
- class ResultData[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability indicator’
Te_Percentage: float: float Percentage of TEs Unit: %
Te_Outside: int: decimal Number of detected TEs
Te_Total: int: decimal Number of measured values
- calculate(mimo=Mimo.Default) CalculateStruct [source]
# SCPI: CALCulate:WLAN:MEASurement<Instance>:MEValuation:PVTime:MIMO<n>:TEDistrib value: CalculateStruct = driver.multiEval.powerVsTime.mimo.teDistribution.calculate(mimo = repcap.Mimo.Default)
Return the scalar results for timing error (TE) distribution for MIMO. The commands are only supported for OFDM standards. Exceeding the limit has no impact on the stop ‘On Limit Failure’ condition or out-of-tolerance counter.
- param mimo:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mimo’)
- return:
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch(mimo=Mimo.Default) ResultData [source]
# SCPI: FETCh:WLAN:MEASurement<Instance>:MEValuation:PVTime:MIMO<n>:TEDistrib value: ResultData = driver.multiEval.powerVsTime.mimo.teDistribution.fetch(mimo = repcap.Mimo.Default)
Return the scalar results for timing error (TE) distribution for MIMO. The commands are only supported for OFDM standards. Exceeding the limit has no impact on the stop ‘On Limit Failure’ condition or out-of-tolerance counter.
- param mimo:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mimo’)
- return:
structure: for return value, see the help for ResultData structure arguments.
- read(mimo=Mimo.Default) ResultData [source]
# SCPI: READ:WLAN:MEASurement<Instance>:MEValuation:PVTime:MIMO<n>:TEDistrib value: ResultData = driver.multiEval.powerVsTime.mimo.teDistribution.read(mimo = repcap.Mimo.Default)
Return the scalar results for timing error (TE) distribution for MIMO. The commands are only supported for OFDM standards. Exceeding the limit has no impact on the stop ‘On Limit Failure’ condition or out-of-tolerance counter.
- param mimo:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mimo’)
- return:
structure: for return value, see the help for ResultData structure arguments.